and 2.5mm is the cross sectional area of the individual live or neutral wires in the 1.5mm or 2.5mm cable. This is not the combined cross sectional area. Each one of the live and neutral wires has a cross sectional area of 1.5mm or 2.5mm.

Section 534 applies to AC power circuits only. When the need for power SPDs is identified, additional SPDs on other services such as telecommunications lines and equipment is also recommended. See BS EN 62305 and BS EN 61643. It follows that single-core non-sheathed insulated conductors must be protected by conduit or trunking and be terminated within a suitable enclosure. is the maximum fault current the breaker can interrupt safely, although the breaker may no longer be usable. les is the maximum fault current the breaker can interrupt safely without loss of performance. lenThe first table below is for cables which are installed by Method 103 “Surrounded by thermal insulation including in a stud wall with thermal insulation with cable not touching the wall”. Some distributors will specify a maximum permitted length for consumer's tails. The distributor may also apply pa rticular requirements for isolation or protection. 132.16 Provides a concise outline of the new IET Wiring Regulations 18 th Edition and BS 7671:2018 Requirements for Electrical Installations

An adequate separation between telecommunication wiring (Band I) and electric power and lighting (Band II) circuits must be maintained. This is to prevent mains voltage appearing in telecommunication circuits with consequent danger to personnel. BS 6701:2004 recommends that the minimum separation distances given in Tables 7.4.2(i) and 7.4.2(ii) should be maintained.Temporary generators can be divided into two classes, i.e. portable and mobile: portable generators with an electrical output rating of up to 10 kVA are used for small-scale work for short-term use, i.e. less than one day, and .,.. mobile generators are those used for longer periods and can be in excess of 10 kVA output. ll> BS 3036 cb/RCBO Type B cb/RCBO Type C cb/RCBO Type D BS 3036 cb/RCBO Type B cb/RCBO Type C cb/RCBO Type D damage caused by any error or omission in the work, whether such an error or omission is the result

The bare wire, when the cable is used, should be marked with a green and yellow earth sleeve. This should be cut to length and slipped over the wire before it’s connected up. a) be at least 50 mm from the top or bottom, as appropriate, or (b) have earthed armouring or an earthed metal sheath, or (c) be enclosed in earthed steel conduit or trunking, or (d) be provided with mechanical protection sufficient to prevent penetration of the cable by nails, screws and the like (Note: the requirement to prevent penetration is difficult to meet), or (e) form part of a SELV or PELV circuit. All final circuits of the location comply with the requirements for automatic disconnection according to Regulation 411.3.2.

Before starting work on an installation which requires a new electrical supply, the installer should establish the following information with the local electricity distributor: (a) the number of live conductors required by the design (b) the distributor's requirement for cross-sectional area and maximum* length of the consumer's tails (c) the maximum prospective fault current (lpf) at the supply terminals (d) the typical maximum earth fault loop impedance (Ze) of the earth fault path outside the consumer's installation (e) the type and rating of the distributor's fusible cut-out or protective device (f) the distributor's requirements regarding the size of main protective bonding conductors (g) the conductor arrangement and system earthing (h) the arrangements for the incoming cable and metering.