While the AWG is essentially identical to the Brown & Sharpe (B&S) sheet metal gauge, the B&S gauge was designed for use with sheet metals as its name suggests. These are functionally interchangeable but the use of B&S in relation to wire gauges, rather than sheet metal gauges, is technically improper. The n gauge wire resistance R in ohms per kilofeet (Ω/kft) is equal to 0.3048×1000000000 times the wire's resistivity ρ in The largest diameter AWG size is 0000 (4/0) which is pronounced ‘four aught’, representing a diameter of .46″. The smallest diameter is 32 AWG, representing .00795″.

conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). The n gauge wire diameter d n in inches (in) is equal to 0.005in times 92 raised to the power of 36 minus gauge number n, divided by 39: The AWG tables are for a single, solid and round conductor. The AWG of a stranded wire is determined by the cross-sectional area of the equivalent solid conductor. Because there are also small gaps between the strands, a stranded wire will always have a slightly larger overall diameter than a solid wire with the same AWG. AWG sizes do not fit perfectly into mm or inches, so you may need to round up or down when safe to do so.

The number of devices connected to the circuit usually determines how much current will flow through the wire. The wire size chart below shows allowable ampacities of insulated conductors rated up to and including product/helpAdviseTab.hbs -->

AWG or American Wire Gauge is the US standard measure for the diameter of electrical conductors. The American Wire Gauge chart is based on the number of dies originally required to draw the copper down to the required dimensional size. It means the higher the AWG number is, the smaller the wire diameter is. Our Belden cables and the pairs in instrumentation cable are some of the electrical cables where the conductor size is expressed as an AWG figure. Our Tri-Rated cable, compliant with American standard UL758, can be converted to AWG cable conductor sizes if required. Increasing gauge numbers denote logarithmically decreasing wire diameters, which is similar to many other non-metric gauging systems such as British Standard Wire Gauge (SWG). However, AWG is dissimilar to IEC 60228, the metric wire-size standard used in most parts of the world, based directly on the wire cross-section area (in square millimetres, mm²). The AWG originated in the number of drawing operations used to produce a given gauge of wire. Very fine wire (for example, 30gauge) required more passes through the drawing dies than 0gauge wire did. Manufacturers of wire formerly had proprietary wire gauge systems; the development of standardized wire gauges rationalized selection of wire for a particular purpose. The n gauge wire resistance R in ohms per kilometer (Ω/km) is equal to 1000000000 times the wire's resistivity ρ in The AWG table below is for a single, solid, round conductor. Because of the small gaps between the strands in a stranded wire, a stranded wire with the same current-carrying capacity and electrical resistance as a solid wire, always have a slightly larger overall diameter.The AWG gauge system only applies for solid, round, non-ferrous conducting wires. Keep this in mind when evaluating wire size and type for your application, as AWG doesn’t apply to stranded or non-round wires. AWG Gauge Sizes for Home Wiring, Auto Wiring, and Boat Wiring Calculate the number of small circles that fits into an outer larger circle - ex. how many pipes or wires fits into a larger pipe or conduit. a>

in millimeters (mm) is equal to 0.127mm times 92 raised to the power of 36 minus gauge number n, divided by 39: Wire Gauges run low to high - this means that the smaller a gauge number, the larger it is in mm. Conversely, a large number in AWG equates to a very small number of mm.The most common method of referring to conductor sizes uses the cross-sectional area, expressed in mm². The following AWG metric conversion table converts AWG to mm and inches, and also lists the cross sectional area (mm2). AWG Metric Conversion Chart (AWG to mm) The n gauge wire diameter d n in millimeters (mm) is equal to 0.127mm times 92 raised to the power of 36 minus gauge number n, divided by 39: For more information regarding wiring and cables, see our comprehensive guide here. AWG Gauge Table AWG gauge When calclating AWG from diameter or cross sectional area, the diameter and cross sectional area are rounded to the nearest AWG equivalent values. Wire diameter calculation In the US, the most commonly used wire gauge system is AWG, or American Wire Gauge. The higher the gauge number, the smaller the wire.

When buying cut to length electrical wire or electrical cable, many UK and international buyers face difficulty when confronted with AWG sizing. Vice Versa, American buyers may be stumped when they are recommended a certain gauge of cable or wire, and don't know how to get it when confronted with mm. Electric resistance in wire made of Copper, Aluminum, Brass, Constantan, Nichrome, Platinum, Silver or Tungsten.

Translate this Page

What is AWG? The AWG standard was created by the Brown & Sharpe Company, a leading manufacturer of machinist technology in the late 1800s & early 1900s. The AWG standard was officially adopted & implemented as industry-standard sizing in 1857. Unfortunately, AWG does not fit comfortably in rounded mm or inches, so there will always need to be a small amount of rounding up or down depending on your need or purpose. If you want the technical formulae for converting between the two, it is as follows; American Wire Gauge ( AWG) is a logarithmic stepped standardized wire gauge system used since 1857, predominantly in North America, for the diameters of round, solid, nonferrous, electrically conducting wire. Dimensions of the wires are given in ASTM standard B 258. [1] The cross-sectional area of each gauge is an important factor for determining its current-carrying capacity.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment